Fault Information


Fault Code Description
The position deviations between the current measurement and measurement conducted with the new actuator with the exhaust-gas recirculation valve opened and closed are calculated in the adaptation phase of the exhaust-gas recirculation valve.
The long-term drift fault of the exhaust-gas recirculation valve is detected if the absolute difference between the newly taught-in adaptation value and the adaptation value taught-in during the first cycle exceeds the limit value.
Limit value: 6.01 %
Fault Code Conditions
General Conditions The check takes place when the exhaust-gas recirculation valve adaptation function is active.
Control unit voltage: 9.5 V to 16 V.
Terminal Condition

Driving Conditions
Fault Time Condition
Service Plan
For electrical EGR valve:
Replace EGR valve.
For pneumatic EGR valve:
Check vacuum system between following components and repair if necessary:
- Vacuum reservoir.
- Vacuum fuel tank.
- Pressure converter for bypass flap of EGR cooler.
- Vacuum unit for bypass flap of EGR cooler (diaphragm may be torn).
- Pressure converter for EGR valve.
- Vacuum unit for EGR valveĀ (diaphragm may be torn).
Look out for porous/cracked hoses!
If the vacuum system is OK:
Replace EGR valve.
Fault Impact
None
Warnings
Warning Lights None
Control Center Messages
Service Notes
If the exhaust-gas recirculation valve has been replaced, the following service function must be carried out: Delete adaptations, air mass system.