Fault Code Description |
---|
Control unit: Convertible top module (CVM) Component: Angle-of-rotation sensor, fin Short circuit to ground or line disconnection was detected. Signal of the angle-of-rotation sensor on the control unit input is less than 0.5 V. |
Fault Code Conditions | |
---|---|
General Conditions |
Supply voltage greater than 9 V. |
Terminal Condition |
Terminal 30 on |
Driving Conditions |
Fault Time Condition |
---|
Error debounce: 100 ms |
Service Plan |
---|
Check lines and plug connections between CVM and angle-of-rotation sensorCheck the angle-of-rotation sensor |
Fault Impact |
---|
Soft top can possibly not be moved completely. |
Warnings | |
---|---|
Warning Lights |
Check Control message (558): Check roof lock! |
Control Center Messages |
Service Notes |
---|
|