Fault Code Description |
---|
The diagnosis is monitoring the communication line between the DME and Natural Vacuum Leak Detection (NVLD). Fault monitoring conditions: The fault is detected when there is a line disconnection. |
Fault Code Conditions | |
---|---|
General Conditions |
Temperature precondition: - None Time precondition: - None Other preconditions: - Engine running. Control unit voltage: 9 V to 16 V. |
Terminal Condition |
Terminal 15 on |
Driving Conditions |
Fault Time Condition |
---|
The fault is entered immediately. |
Service Plan |
---|
Check Natural Vacuum Leak Detection voltage supply. Check lines and plug connections between the following components: -DME - NVLD |
Fault Impact |
---|
- None |
Warnings | |
---|---|
Warning Lights |
None |
Control Center Messages |
Service Notes |
---|
- None. |