Fault Information


Fault Code Description
Diagnosis monitors oxygen sensor emissions control. The mixture is too rich and oxygen sensor emissions control makes it leaner.
Fault monitoring conditions:
The fault is detected whenever the mixture is made 30% leaner for longer than 30 seconds.
Fault Code Conditions
General Conditions Other voltage related preconditions:
- Supply voltage between 9 V and 16 V.
Temperature related-precondition:
- None
Time related-precondition:
- None
Other preconditions:
- Engine on.
- Tank ventilation system not active.
Terminal status:
- Terminal 15 on.
Terminal Condition

Driving Conditions
Fault Time Condition
The fault code is logged if it exists for longer than 30 s
Service Plan
If additional faults are entered for the following components, these must be processed first:
- Oxygen sensor before catalytic converter.
- Hot film air mass meter.
- Intake pipe vacuum sensor.
- Intake air temperature sensor.
- Camshaft sensor.
- High-pressure fuel system.
- Low pressure fuel system.
- Check differentiated air intake system for tightness, while doing so check the following components as well:
- Crankcase ventilation.
- Oil cap.
- Tank ventilation system.
Check exhaust system for leak tightness.
Replace injectors.
Fault Impact
- None
- The engine operates in its emergency program.
- Power reduction.
Warnings
Warning Lights Emissions warning light
Control Center Messages
Service Notes
- None.