Fault Code Description |
---|
Diagnosis monitors oxygen sensor emissions control. The mixture is too rich and oxygen sensor emissions control makes it leaner. Fault monitoring conditions: The fault is detected whenever the mixture is made 30% leaner for longer than 30 seconds. |
Fault Code Conditions | |
---|---|
General Conditions |
Other voltage related preconditions: - Supply voltage between 9 V and 16 V. Temperature related-precondition: - None Time related-precondition: - None Other preconditions: - Engine on. - Tank ventilation system not active. Terminal status: - Terminal 15 on. |
Terminal Condition |
|
Driving Conditions |
Fault Time Condition |
---|
The fault code is logged if it exists for longer than 30 s |
Service Plan |
---|
If additional faults are entered for the following components, these must be processed first: - Oxygen sensor before catalytic converter. - Hot film air mass meter. - Intake pipe vacuum sensor. - Intake air temperature sensor. - Camshaft sensor. - High-pressure fuel system. - Low pressure fuel system. - Check differentiated air intake system for tightness, while doing so check the following components as well: - Crankcase ventilation. - Oil cap. - Tank ventilation system. Check exhaust system for leak tightness. Replace injectors. |
Fault Impact |
---|
- None - The engine operates in its emergency program. - Power reduction. |
Warnings | |
---|---|
Warning Lights |
Emissions warning light |
Control Center Messages |
Service Notes |
---|
- None. |