Fault Code Description |
---|
Diagnosis monitors oxygen sensor emissions control. The mixture is too lean and oxygen sensor emissions control makes it richer. Fault monitoring conditions: The fault is detected whenever the mixture needs to be made 30% richer. |
Fault Code Conditions | |
---|---|
General Conditions |
Other voltage preconditions: - Supply voltage between 9 V and 16 V. Temperature precondition: - None Time precondition: - None Other preconditions: - Engine on. - Tank ventilation system not active. Terminal status: - Terminal 15 on. |
Terminal Condition |
|
Driving Conditions |
Fault Time Condition |
---|
The fault code is logged if it exists for longer than 30 s |
Service Plan |
---|
If additional faults are entered for the following components, these must be processed first: - Oxygen sensor before catalytic converter. - Hot film air mass meter. - Intake pipe vacuum sensor. - Intake air temperature sensor. - Camshaft sensor. - High-pressure fuel system. - Low pressure fuel system. Check exhaust system for leak tightness. Replace injectors. |
Fault Impact |
---|
- None - None |
Warnings | |
---|---|
Warning Lights |
Malfunction indicator lamp |
Control Center Messages |
Service Notes |
---|
- None. |