Fault Information


Fault Code Description
Diagnosis monitors oxygen sensor emissions control. The mixture is too lean and oxygen sensor emissions control makes it richer.
Fault monitoring conditions:
The fault is detected whenever the mixture needs to be made 30% richer.
Fault Code Conditions
General Conditions Other voltage preconditions:
- Supply voltage between 9 V and 16 V.
Temperature precondition:
- None
Time precondition:
- None
Other preconditions:
- Engine on.
- Tank ventilation system not active.
Terminal status:
- Terminal 15 on.
Terminal Condition

Driving Conditions
Fault Time Condition
The fault code is logged if it exists for longer than 30 s
Service Plan
If additional faults are entered for the following components, these must be processed first:
- Oxygen sensor before catalytic converter.
- Hot film air mass meter.
- Intake pipe vacuum sensor.
- Intake air temperature sensor.
- Camshaft sensor.
- High-pressure fuel system.
- Low pressure fuel system.
Check exhaust system for leak tightness.
Replace injectors.
Fault Impact
- None
- None
Warnings
Warning Lights Malfunction indicator lamp
Control Center Messages
Service Notes
- None.