Fault Information


Fault Code Description
Diagnosis monitors oxygen sensor emissions control. The mixture is too rich and is made leaner through the oxygen sensor emissions control.
Fault monitoring conditions:
The fault is detected whenever the mixture must be made 30% leaner for longer than 30 seconds.
Fault Code Conditions
General Conditions Temperature precondition:
- None
Time precondition:
- None
Other preconditions:
- Engine running.
- Tank ventilation system not active.
Control unit voltage: 9 V to 16 V.
Terminal Condition Terminal 15
on
Terminal Condition PRD status: Driving

Terminal Condition PRD status: Testing-analysis-diagnosis

Driving Conditions Note: The designations of terminal status or PWF status apply according to the vehicle electrical system of the vehicle.
Fault Time Condition
The fault code is entered if it exists for longer than 30 s
Service Plan
If additional faults are entered for the following components, these must be processed first:
- Oxygen sensor before catalytic converter
- Hot film air mass meter
- Intake pipe pressure sensor
- Intake air temperature sensor
- Camshaft sensor
- High-pressure fuel system
- Low-pressure fuel system
- Valvetronic intake adjuster
- VANOS adjustment unit
- Voltage supply sensor system/actuator 5 V
Check air intake system for tightness, checking the following components as well at the same time:
- Crankcase ventilation
- Oil cap
- Tank ventilation system
Check exhaust system for leak tightness.
Rule out poor fuel grade.
Renew injectors and then reset adaptations.
Fault Impact
- Lack of power.
- Rough engine running.
Warnings
Warning Lights Malfunction indicator lamp
Control Center Messages
Service Notes