Fault Information


Fault Code Description
The diagnosis monitors the lines of the five position sensors.
Malfunction monitoring conditions
Technical details are not relevant for troubleshooting in Service.
Fault Code Conditions
General Conditions Voltage precondition
- Vehicle voltage between 9V and 16V
Temperature condition
- None
Time condition
- None
Other preconditions
- None
Terminal status
- Terminal 15
Terminal Condition

Driving Conditions
Fault Time Condition
The fault is entered immediately.
Service Plan
- 0x2DD6: Program DME if integration level is less than 10-09-511
- 0x135808: Program DME if integration level is less than 10-09-511
‐ Check wiring harness between Valvetronic servomotor and DME
- Replace Valvetronic servomotor. Then perform running-in phase.
Fault Impact
- The load is controlled via the throttle valve (full driving capability/power)
Warnings
Warning Lights none
Control Center Messages
Service Notes
- None