Fault Code Description |
---|
The diagnosis monitors the lines of the five position sensors. Malfunction monitoring conditions Technical details are not relevant for troubleshooting in Service. |
Fault Code Conditions | |
---|---|
General Conditions |
Voltage precondition - Vehicle voltage between 9V and 16V Temperature condition - None Time condition - None Other preconditions - None Terminal status - Terminal 15 |
Terminal Condition |
|
Driving Conditions |
Fault Time Condition |
---|
The fault is entered immediately. |
Service Plan |
---|
- 0x2DD6: Program DME if integration level is less than 10-09-511 - 0x135808: Program DME if integration level is less than 10-09-511 ‐ Check wiring harness between Valvetronic servomotor and DME - Replace Valvetronic servomotor. Then perform running-in phase. |
Fault Impact |
---|
- The load is controlled via the throttle valve (full driving capability/power) |
Warnings | |
---|---|
Warning Lights |
none |
Control Center Messages |
Service Notes |
---|
- None |