Fault Information


Fault Code Description
The diagnosis monitors activation of heating at the oxygen sensor before catalytic converter.
Malfunction monitoring conditions
The fault is detected when there is a line disconnection (break).
Fault Code Conditions
General Conditions Voltage precondition
- Supply voltage between 9 V and 16 V
Temperature condition
- None
Time condition
- 10 s after engine on
Other preconditions
- Engine ON
Terminal status
- Terminal 15 on
Terminal Condition

Driving Conditions
Fault Time Condition
The fault is entered within 10 seconds.
Service Plan
- Eliminate secondary faults, faults for the following components or functions:
Check terminal 15 N_1 lines and plug connections between following components:
DME
Oxygen sensor before catalytic converter
- Check oxygen sensor before catalytic converter.
- Replace oxygen sensor before catalytic converter.
Fault Impact
- None
Warnings
Warning Lights Emissions warning light
Control Center Messages
Service Notes
- The internal resistance of the oxygen sensor heating can be measured when disconnected/removed. A resistance greater than 1000 ohms can be measured between pin 4 (12 V) and pin 3 (ground) in the event of a fault and when the sensor is cold (less than 50°C).
- Do not allow plug connection to come into contact with cleaning agents or solvents, oxygen sensor can be destroyed.