Fault Code Description |
---|
The diagnosis monitors activation of heating at the oxygen sensor before catalytic converter. Malfunction monitoring conditions The fault is detected when there is a line disconnection (break). |
Fault Code Conditions | |
---|---|
General Conditions |
Voltage precondition - Supply voltage between 9 V and 16 V Temperature condition - None Time condition - 10 s after engine on Other preconditions - Engine ON Terminal status - Terminal 15 on |
Terminal Condition |
|
Driving Conditions |
Fault Time Condition |
---|
The fault is entered within 10 seconds. |
Service Plan |
---|
- Eliminate secondary faults, faults for the following components or functions: Check terminal 15 N_1 lines and plug connections between following components: DME Oxygen sensor before catalytic converter - Check oxygen sensor before catalytic converter. - Replace oxygen sensor before catalytic converter. |
Fault Impact |
---|
- None |
Warnings | |
---|---|
Warning Lights |
Emissions warning light |
Control Center Messages |
Service Notes |
---|
- The internal resistance of the oxygen sensor heating can be measured when disconnected/removed. A resistance greater than 1000 ohms can be measured between pin 4 (12 V) and pin 3 (ground) in the event of a fault and when the sensor is cold (less than 50°C). - Do not allow plug connection to come into contact with cleaning agents or solvents, oxygen sensor can be destroyed. |