Fault Information


Fault Code Description
Monitoring deviation test, rail pressure sensor. The fault is detected if the non-linearised value of the rail pressure (voltage) upon engine start or during after-run of the control unit exceeds the limit value (excessive positive offset).
Engine start limit value: 384 mV
After-run limit value: 384 mV
Fault Code Conditions
General Conditions Monitoring takes place continuously if no electrical faults are set.
Control unit voltage: 9.5 V to 16 V.
Terminal Condition

Driving Conditions
Fault Time Condition
At start: 30 ms
During control unit after-run: 100 ms
Service Plan
1. Check line and plug connections
- Check connections for corrosion!
- Check connectors for correct locking!
2. Carry out function check.
If checks mentioned above are OK: Replace rail pressure sensor.
Fault Impact
Visit your nearest BMW Service Centre.
Warnings
Warning Lights None
Control Center Messages
Service Notes
If the rail pressure sensor was renewed, the following service function must be performed: Delete adaptations, fuel system.