Fault Information


Fault Code Description
The diagnosis monitors teaching of the limit position of the electrical wastegate valve.
Fault monitoring conditions:
The fault is detected if the located limit position (open position) is outside the valid range.
Fault Code Conditions
General Conditions Temperature precondition:
- None
Time precondition:
- None
Other preconditions:
- A lower limit position was learned as valid.
Control unit voltage: 9 V to 16 V.
Terminal Condition Terminal 15
on
Driving Conditions
Fault Time Condition
The fault is entered within 10 seconds.
Service Plan
- Check linkage (stiff movement, damage and wear).
- Check setting of linkage with system test.
- Replace electrical controller drive, wastegate valve.
Fault Impact
- None
Warnings
Warning Lights None
Control Center Messages
Service Notes
- None.