Fault Code Description |
---|
The diagnosis monitors whether the Valvetronic servomotor has reached the maximum stroke in the event of an open circuit. Fault monitoring conditions: The fault is detected if a line disconnection was detected and the maximum stroke was not reached. |
Fault Code Conditions | |
---|---|
General Conditions |
Temperature precondition: - None Time precondition: - None Other preconditions: - None Control unit voltage: 9 V to 16 V. |
Terminal Condition |
Terminal 15 on |
Driving Conditions |
Fault Time Condition |
---|
The fault is entered immediately. |
Service Plan |
---|
Consequential fault, rectify faults relating to the following components or functions: - Valvetronic, electrical faults. |
Fault Impact |
---|
- The engine operates in its emergency program. Breakdown possible. |
Warnings | |
---|---|
Warning Lights |
Malfunction indicator lamp and Check Control message |
Control Center Messages |
Service Notes |
---|
- None. |