Fault Code Description |
---|
VDP: Fault in the valve activation of the air supply system |
Fault Code Conditions | |
---|---|
General Conditions |
Voltage at the control unit between 9 V and 16 V |
Terminal Condition |
PWF status: Driving |
Terminal Condition |
PWF status: Testing-analysis-diagnosis |
Driving Conditions |
Fault Time Condition |
---|
Stored within 100 ms |
Service Plan |
---|
1. Perform visual inspection 2. Line check of supply lines 3. Check the connection between the pins of the valves on the air supply system and terminal 30/terminal 31 4. Measure the coil resistance of the valve 5. Check the supply voltage of the valve |
Fault Impact |
---|
Failure of self-levelling suspension |
Warnings | |
---|---|
Warning Lights |
CC message: Chassis. Possible to continue journey. CC message: Chassis and suspension. Restricted cornering behaviour! |
Control Center Messages |
Service Notes |
---|
In the event of a fault the entire air supply system including valve block must be renewed. Possible fault causes: Short circuit KL15/KL30Short circuit terminal 31Short circuit in coil windingLine disconnection |