Fault Information


Fault Code Description

The diagnosis monitors the EME for internal faults.
The fault is detected if an internal current level in the DC/DC converter exceeds the maximum value permitted.
Fault Code Conditions
General Conditions Vehicle voltage between 9V and 16V
Terminal Condition Terminal 15
on
Terminal Condition Terminal 30B
on
Driving Conditions
Fault Time Condition
The fault is entered immediately.
Service Plan
Measure output current and output voltage of the DC/DC converter in accordance with the Troubleshooting Manual.If the DC/DC converter provides the required output current, continue troubleshooting in the 12 V vehicle electrical system: Check positive battery cable, battery earth lead, consumer and 12 V battery for short circuit. If the DC/DC converter does not supply the required output current: Check error details. If the fault is currently present or there is a customer complaint regarding charging of the 12 V battery, renew the EME.
Fault Impact
12 V battery is not charged, breakdown possible.

Warnings
Warning Lights none
Control Center Messages
Service Notes
None