Fault Information


Fault Code Description
The SCR exhaust emission system is being monitored. The fault is detected if the efficiency is too low.
Fault Code Conditions
General Conditions
Control unit voltage: 9.5 V to 16 V.
Terminal Condition

Driving Conditions
Fault Time Condition
No debounce.
Service Plan
1. Check functioning of metering module (spray test), replace in the event of a malfunction.
2. Carry out an SCR system test using the diagnosis system.
Fault Impact
None
Warnings
Warning Lights None
Control Center Messages
Service Notes
Carry out the following service functions depending on which components have been renewed:
- AdBlue: SCR system adjustments and adaptations, AdBlue (long-term adaptation factor).
- Nitrogen oxide sensors: SCR system adjustments and adaptations, SCR exhaust emission sensor system.
- Diesel particulate filter: Diesel particulate filter: register exchange.
- SCR catalytic converter: SCR catalytic converter: register exchange.
- Metering module: SCR system adjustments and adaptations, SCR metering module.
- SCR tank system: SCR system adjustments and adaptations, SCR tank system.
The fault cannot be deleted until the DDE has detected a functioning SCR system. For this purpose, complete a conditioning run until the Check Control message goes out. The fault memory can then be deleted.