Fault Code Description |
---|
The SCR exhaust emission system is being monitored. The fault is detected if the efficiency is too low. |
Fault Code Conditions | |
---|---|
General Conditions |
Control unit voltage: 9.5 V to 16 V. |
Terminal Condition |
|
Driving Conditions |
Fault Time Condition |
---|
No debounce. |
Service Plan |
---|
1. Check functioning of metering module (spray test), replace in the event of a malfunction. 2. Carry out an SCR system test using the diagnosis system. |
Fault Impact |
---|
None |
Warnings | |
---|---|
Warning Lights |
None |
Control Center Messages |
Service Notes |
---|
Carry out the following service functions depending on which components have been renewed: - AdBlue: SCR system adjustments and adaptations, AdBlue (long-term adaptation factor). - Nitrogen oxide sensors: SCR system adjustments and adaptations, SCR exhaust emission sensor system. - Diesel particulate filter: Diesel particulate filter: register exchange. - SCR catalytic converter: SCR catalytic converter: register exchange. - Metering module: SCR system adjustments and adaptations, SCR metering module. - SCR tank system: SCR system adjustments and adaptations, SCR tank system. The fault cannot be deleted until the DDE has detected a functioning SCR system. For this purpose, complete a conditioning run until the Check Control message goes out. The fault memory can then be deleted. |