Fault Information


Fault Code Description
Dynamic monitoring of NOx sensor before SCR catalytic converter. Dynamic monitoring evaluates the time characteristic of the sensor signal during the transition from load to overrun mode. With an intact sensor, the signal delay must not be greater than a limit value.
Limit value: Between 1 s and 4 s (depending on variant).
Fault Code Conditions
General Conditions The monitoring only takes place when the following conditions are met:
- The status of the NOx sensor is valid.
- No fault code is logged for the NOx sensor and exhaust gas recirculation.
Control unit voltage: 9.5 V to 16 V.
Terminal Condition

Driving Conditions
Fault Time Condition
The fault is entered if it has been detected more than the following number of times (fault debouncing counter): between 3 and 50 (depending on variant).
Service Plan
Replace the NOx sensor before SCR catalytic converter.
Fault Impact
Warnings
Warning Lights None
Control Center Messages
Service Notes
If a nitrogen oxide sensor is replaced, the following service function must be carried out: SCR system adjustments and adaptations, SCR exhaust emission sensor system.