Fault Information


Fault Code Description
The adjustment value of the nitrogen oxide sensor after SCR catalytic converter is being monitored. The fault is detected if the taught-in adjustment value exceeds the limit value.
Limit value: 30 ppm
Fault Code Conditions
General Conditions
Control unit voltage: 9.5 V to 16 V.
Terminal Condition

Driving Conditions
Fault Time Condition
The fault is entered if it has been detected more than the following number of times (fault debouncing counter): 65535
Service Plan
Replace nitrogen oxide sensor after SCR catalytic converter.
Fault Impact
Warnings
Warning Lights None
Control Center Messages
Service Notes
If a nitrogen oxide sensor is replaced, the following service function must be carried out: SCR system adjustments and adaptations, SCR exhaust emission sensor system.