Fault Code Description |
---|
Monitoring of the adaptation values of the nitrogen oxide sensor before the SCR catalytic converter. If the adaptation value exceeds a limit value, the fault is detected. Limit value: 30 ppm |
Fault Code Conditions | |
---|---|
General Conditions |
- Control unit voltage: 9.5 V to 16 V. |
Terminal Condition |
|
Driving Conditions |
Fault Time Condition |
---|
The fault is entered if it has been detected more than the following number of times (fault debouncing counter): 65535 |
Service Plan |
---|
1. If the frequency counter of the fault is 1: Delete fault. 2. If the fault occurs more than once, replace the NOx sensor before the SCR catalytic converter. |
Fault Impact |
---|
None |
Warnings | |
---|---|
Warning Lights |
None |
Control Center Messages |
Service Notes |
---|
If a nitrogen oxide sensor is replaced, the following service function must be carried out: SCR system adjustments and adaptations, SCR exhaust emission sensor system. |