Fault Information


Fault Code Description
The diagnosis system monitors the voltage signal of the oxygen sensor after catalytic converter in case of change of the mixture.
Fault monitoring conditions:
The fault is detected when the signal voltage of the oxygen sensor is permanently less than 0.8 V.
Fault Code Conditions
General Conditions Temperature precondition:
- Catalytic converter temperature greater than 500°C.
Time precondition:
- Constant exhaust mass flow greater than 50 kg/h.
Other preconditions:
- Engine running.
- Constant-speed driving between 50 km/h and 80 km/h during medium engine speed (1400 rpm to 3240 rpm).
- Duration of the constant-speed driving at least 10 min
- No fault memory entries that indicate a fault in the fuel-air mixture.
Control unit voltage: 11 V to 16 V.
Terminal Condition Terminal 15
on
Driving Conditions
Fault Time Condition
The fault is entered immediately.
Service Plan
Check if faults are entered to the following components/functions, then rectify these first:
- Fuel system
- Variable camshaft timing control
- Tank ventilation
- Ignition
- Injection system
- Crankshaft sensor
- Camshaft sensor
- Electromotive throttle actuator
- Hot-film air mass meter
Check exhaust system for leak tightness.
Check wiring harness between DME and oxygen sensor after catalytic converter.
Check crankcase ventilation.
Renew oxygen sensor after catalytic converter.
Fault Impact
- None
Warnings
Warning Lights Malfunction indicator lamp
Control Center Messages
Service Notes
Plug connection should not come in contact with cleaning agents or solvents, damage to the oxygen sensor is possible.