Fault Code Description |
---|
Fault Code Conditions |
---|
Fault Time Condition |
---|
DME: VANOS intake |
Service Plan |
---|
'A' Camshaft Position - Timing Over-Retarded (Bank 1) |
Fault Impact |
---|
Voltage condition: - Electrical system voltage > 10 V Temperature condition: - Engine temperature between 0 °C and 110 °C Time condition: - None Other conditions: - Start process terminated, engine running none The fault is recognized when the VANOS fails to trail the specified value within the specified period. Potential problem source(s): - Extreme contamination on or seizure at VANOS solenoid valve - Stiction or defect in VANOS assembly |
Warnings |
---|
Service Notes |
---|
- Check VANOS solenoid valve for contamination, respond to severe contamination by removing filter screen with tab - Install new solenoid valve (valve seized) - Replace VANOS unit - 'Always proceed step-by-step - Check system after each step (clear control module fault memory and test operation)' |