Fault Information


Fault Code Description
Fault Code Conditions
Fault Time Condition
DME: DMTL, system fault
Service Plan

Diagnostic Module Tank Leakage (DM-TL) Pump Current Too High
Fault Impact
Voltage condition:
10.95 V < electrical system voltage < 16 V
Temperature condition:
None
Time condition:
None
Other conditions:
none
none

The fault is recognized when the current draw exceeds 40 mA.

Potential problem source(s):
- DMTL (leakage diagnosis pump) defective

Warnings
Service Notes
1. If DTCs related to the DMTL Diagnostic Module for Tank Leaks are logged delete all trouble codes from the error memory
2. Perform DMTL operational check
3. If the fault cannot be reproducd in the DMTL operational check terminate the repair procedure!
4. If the fault can be reproduced with the DMTL operational test, then replace the DMTL.