Fault Information


Fault Code Description
Fault Code Conditions
Fault Time Condition
DME: VANOS intake
Service Plan

'A' Camshaft Position - Timing Over-Retarded (Bank 1)
Fault Impact
Voltage condition:
Electrical system voltage above 10 V

Other conditions:
- Start process terminated, engine running
Terminal 15

Engine temperature between 0°C and 110°C
Oil temperature less than 120 or 134°C, varies according to engine speed
No travel limit adaptation fault after power failure on the respective cylinder bank
No travel limit adaptation fault on the respective cylinder bank
Camshaft flank recognized
Specified VANOS value between 70° and 120°

Warnings
Service Notes
1. Check VANOS solenoid valve for contamination, if serious contamination is present remove filter screen with tab
2. Install new solenoid valve (valve sticking)
3. Replace VANOS assembly
'Always proceed step-by-step - Check system after each step (clear control module fault memory and test operation)'