Fault Code Description |
---|
Fault Code Conditions |
---|
Fault Time Condition |
---|
Inlet VANOS 2 |
Service Plan |
---|
'A' Camshaft Position - Timing Over-Retarded (Bank 2) |
Fault Impact |
---|
none KL_15 = true Bank 2 intake controller monitor (max. control deviation (differential spec./actual data) is 5°KW) VANOS may not be at travel limit, that is Vsa2_sprs<120°KW. |
Warnings |
---|
Service Notes |
---|
Test sequence (after each step stop to determine whether fault is present): 1. If the corresponding camshaft fault has been logged, start by checking the camshaft sensor 2. Check oil level 3. Check VANOS valve for contamination 4. Replace solenoid valve 5. Replace VANOS adjustment mechanism |