Monitoring of the swirl-flap controller position.
The monitoring checks whether the signal of the position sensor moves in a physically sensible value range.
The fault is detected if the sensor signal (voltage) lies between a lower and a upper limit value.
Lower limit value: 250 mV
Upper limit value: between 440 mV and 840 mV (depending on variant).
Fault Code Conditions
General Conditions Monitoring takes place continuously if no faults of voltage supply are available.
Control unit voltage: 9.5 V to 16 V.
Terminal Condition PRD status: Driving

Terminal Condition PRD status: Testing-analysis-diagnosis

Terminal Condition PRD status: Residing

Driving Conditions
Fault Time Condition
The fault is entered if it is present for longer than the following period (debounce time): 10000 ms
Service Plan
1. Check the swirl-flap controller for electrical error. Electrical errors must be rectified first.
2. Check kinematics of the swirl-flap controller. The fault may be caused by a disconnected or broken connection between the controller and the swirl flaps.
3. The fault can be caused by wear in the swirl-flap shaft.
If no additional electrical errors have been entered: Renew the intake system.

Fault Impact
None
Warnings
Warning Lights Malfunction indicator lamp
Control Center Messages
Service Notes
If the swirl flaps are replaced, the following service function must be carried out: Reset adaptations, air mass system.